| Design Feature | Effect on Performance | |
| A | Generant weight, Type & Geometry | Time to First Gas, Onset Slope, Peak Output Pressure, Gas Temperature, Moles of Gas. |
| B | Inflator Length (Gas Volume/Mass) | Peak Output Pressure, Gas Temperature, Moles of Gas. |
| C | Choke (Throat) Diameter | Mass Flow Rate, Onset Slope. |
| D | Stored Gas Helium Content | Mass Flow Rate, Onset Slope. |